top of page

NOVO ASME B 31.1 - 2018

Nova edição do manual ASME B 31.1 - POWER PIPING - 2018 disponível.

Para preço e condições nos contate através de normas@drula.com.br.

Description / Abstract:

Rules for this Code Section have been developed considering the needs for applications that include piping typically found in electric power generating stations, in industrial and institutional plants, geothermal heating systems, and central and district heating and cooling systems. This Code prescribes requirements for the design, materials, fabrication, erection, test, inspection, operation, and maintenance of piping systems. Where service requirements necessitate measures beyond those required by this Code, such measures shall be specified by the engineering design. Piping as used in this Code includes pipe, flanges, bolting, gaskets, valves, pressure-relieving valves/ devices, fittings, and the pressure-containing portions of other piping components, whether manufactured in accordance with standards listed in Table 126.1-1 or specially designed. It also includes hangers and supports and other equipment items necessary to prevent overstressing the pressure-containing components. Rules governing piping for miscellaneous appurtenances, such as water columns, remote water level indicators, pressure gages, and gage glasses, are included within the scope of this Code, but the requirements for boiler appurtenances shall be in accordance with ASME Boiler and Pressure Vessel Code (BPVC), Section I, PG-60. The users of this Code are advised that in some areas legislation may establish governmental jurisdiction over the subject matter covered by this Code. However, any such legal requirement shall not relieve the owner of his/her inspection responsibilities specified in para. 136.1. Power piping systems as covered by this Code ð18Þ apply to all piping and their component parts except as excluded in para. 100.1.3. They include but are not limited to steam, water, oil, gas, and air services. (a) This Code covers boiler external piping as defined below for power boilers and high-temperature, high-pressure water boilers in which steam or vapor is generated at a pressure of more than 15 psig [100 kPa (gage)]; and high temperature water is generated at pressures exceeding 160 psig [1 103 kPa (gage)] and/or temperatures exceeding 250°F (120°C).

Posts Em Destaque
Posts Recentes
Arquivo
Procurar por tags
Nenhum tag.
Siga
  • Facebook Basic Square
  • Twitter Basic Square
  • Google+ Basic Square

Parabéns! Sua mensagem foi recebida.

bottom of page